Inner Corner at Base of Wall Jacksonville FL

The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry.

D And D Masonry Contractors Inc
(904) 743-0807
1525 Romney St
Jacksonville, FL
 
AC Concrete & Masonry
(904) 626-8358
5430 Dakota Dr
Jacksonville, FL
 
Charles Williamson Masonry
(904) 249-7466
814 7th Ave N
Jacksonville, FL
 
Brick IT Inc
(904) 880-9377
12760 Edenbridge Ct
Jacksonville, FL
 
Concrete Creations Of Jacksonville Inc
(904) 880-4733
12637 Philips Hwy
Jacksonville, FL
 
Dedmon Masonry Inc
(904) 744-2860
1525 Romney St
Jacksonville, FL
 
Anderson Masonry Contractor Inc
(904) 268-1717
3768 Kori Rd
Jacksonville, FL
 
Doug's Masonry Inc
(904) 396-9206
6121 Collins Rd Lot 257
Jacksonville, FL
 
Arrow Brick
(904) 786-7555
723 Memorial Park Rd
Jacksonville, FL
 
Custom Concrete Inc
(904) 924-0006
11717 New Kings Rd
Jacksonville, FL
 

Inner Corner at Base of Wall

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: September 1, 2006

By Walter A. Laska

It is difficult for a mason to properly tool mortar joints at inner wall corners due to the size and shape of the jointer and the acute angle formed by the intersecting brick. As a result, the mortar joints at this location cannot be tooled neatly or compactly. Therefore, inner wall corners provide an ideal location for expansion joints.

Expansion joints located at inner corners are easy to construct and are well concealed. The expansion joint should be totally void of any material which might inhibit movement, and the reinforcement must be discontinuous at the expansion joint.

The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry. Also, the connection creates a control joint in the concrete masonry backing along the column interface.
Elevation View

The space between the column and the concrete masonry should be kept free of all mortar bridging. If the column and concrete masonry are tightly bonded, any movement of the column is transferred to the masonry, possibly causing the concrete masonry backing to crack.

Flashing continuity must be maintained at the inner corners. The flashing should be cut, lapped, and set in a continuous bed of mastic to prevent water from flowing under the laps.

Click here to read full article from Masonry Construction